Replace the device in bay X.
HPE Synergy 12Gb SAS Connection Module
Health LED is flashing amber
Symptom
The SAS connection module displays an amber LED.
Action
Check HPE Synergy Console for status alerts that identify the problem.
Review the HPE Synergy 12Gb SAS Connection Module LEDs.
More information
HPE Synergy 12Gb SAS Connection Module front panel LEDs on page 76
The controller locks up during POST
Symptom
Storage is not ready or the controller locks up during POST.
Action
Verify the power up sequence and allow sufficient time for each component to power up.
Unable to access storage
Symptom
The SAS connection module cannot access storage.
Action
Verify the HPE Synergy 12Gb SAS Connection Module and the storage enclosure are supported for use
with each other. For support information, see the HPE Synergy 12Gb SAS Connection Module
QuickSpecs on the Hewlett Packard Enterprise website.
Storage options
Drive issues (hard drives and solid state drives)
Drives are failed
Symptom
Drives are failed.
Hardware issues 65

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HPE Synergy Series and is the answer not in the manual?

HPE Synergy Series Specifications

General IconGeneral
ProcessorIntel Xeon Scalable Processors
StorageSAS/SATA HDD/SSD, NVMe SSD
NetworkingEthernet, Fibre Channel, InfiniBand
ManagementHPE OneView
Compute Modules SupportedHPE Synergy 480 Gen10, HPE Synergy 660 Gen10
Operating System SupportVMware vSphere, Microsoft Windows Server, Red Hat Enterprise Linux, SUSE Linux Enterprise Server
Fabric Modules SupportedHPE Synergy 40Gb F8 Switch Module
Power SuppliesHPE Synergy 12000 Frame Power Supplies (Redundant)

Related product manuals