EasyManua.ls Logo

Huawei RH8100 V3 - Page 28

Huawei RH8100 V3
386 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21 Network port data
transmission status indicator
(The 82599 NIC (BC11FXEB)
indicator is used as an
example.)
22 NIC 1
23 HFC-1 24 VGA port
25 RJ45 serial port 26 iBMC management network
port
27 USB port - -
Fan Description
In Figure 2-10, fans 1 to 3 are used to control the air intake vent temperature for
the front I/O modules, and fans 4 to 8 are used to control the air intake vent
temperature for the compute modules. All the fans support automatic speed
adjustment based on the ambient temperature.
PCIe Slots on the Rear I/O Module
The rear I/O module provides 10 standard PCIe slots. For details about these slots,
see Table 2-6.
The PCIe slots mapping to a vacant compute module slot are unavailable.
Table 2-6 PCIe slots on the rear I/O module
PCI
e
Slo
t
Comp
ute
Modul
e
PC
Ie
St
an
da
rd
Co
nn
ect
or
Ba
nd
wi
dth
Bu
s
Wi
dth
Por
t
Nu
mb
er
Hot
Swap
Bus/Device/
Function
Number
(B/D/F)
Slot Size
Slo
t 1
Comp
ute
modul
e 7
PC
Ie
3.
0
x16 x16 Por
t
3A
Suppor
ted
80/03/00 Full-height
3/4-length
Slo
t 2
Comp
ute
modul
e 6
PC
Ie
3.
0
x8 x8 Por
t
3A
Suppor
ted
C0/03/00 Full-height
3/4-length
RH8100 V3 Server
User Guide 2 About the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 18

Table of Contents

Related product manuals