Table 7-6 Resource allocation of the front I/O module in dual-system
Item System A System B
PCIe
slots of
the
front
I/O
modul
e
Slots 11 to 13 if the FM-A and
PCIe riser cards are congured
Slots 14 to 16 if the FM-A and
PCIe riser cards are congured
RAID RAID-1 RAID-2
Table 7-7 lists the shared resources in dual-system.
Table 7-7 Shared resources in dual-system
Item System A System B
DVD
drive,
LCD
The DVD drive is shared by partitions A and B. You can switch
the DVD drive between partitions A and B using the iBMC
WebUI or LCD.
PSUs,
Fan
modules
,
Backpla
ne
Power supply units (PSUs) are shared by partitions A and B.
The two partitions have the following hardware requirements:
Eight CPUs function properly.
Both CM-1 and CM-5 have at least one DIMM.
The compute modules in slot 1 and slot 5 are installed properly and RAID
controller cards of the same model are installed in the FM.
No miniSAS cable needs to be connected to the RAID controller cards
installed in FM-A. MiniSAS cables must be connected to the RAID
controller cards installed in FM-B, FM-C, or FM-D.
Assign PCIe slots. For example, assign PCIe slots 6 to 10 to partition A
and PCIe slots 1 to 5 to partition B.
NO TICE
To reserve and use single-system hard disk data in dual-system:
The hard disks in a virtual drive of the single-system must be in the same
partition. Otherwise, the hard disk data is not available after the switchover.