Category Item Specications
Weight Maximum weight:
8-bay server: 152 kg (335.10 lb)
12-bay server: 160 kg (352.74 lb)
24-bay server: 165 kg (363.76 lb)
Packaging material weight: 20 kg (44.10 lb)
Environmental
specications
Temperature Operating temperature: 5°C to 40°C (41°F
to 104°F) (ASHRAE Class A3 compliant)
NOTE
When the 64 GB DIMMs or high-power GPUs are
congured, the maximum operating temperature is
35°C (95°F).
Storage temperature: -40°C to +65°C (-40°F
to +149°F)
Temperature change rate: < 20°C/h
(36°F/h)
Long-term storage temperature: 21°C to
27°C (69.8°F to 80.6°F)
Humidity Operating humidity: 10% RH to 90% RH
(non-condensing)
Storage humidity: 5% RH to 95% RH (non-
condensing)
Humidity change rate: < 20% RH/h
Long-term storage humidity: 30% RH to
69% RH
Altitude ≤ 3000 m (9842.40 ft)
The highest operating temperature
decreases by 1°C (1.8°F) with every
increase of 300 m (984.24 ft) in an altitude
above 900 m (2952.72 ft).
At an altitude of over 3000 m (9842.5 ft),
only Titanium PSUs can be used.
HDDs are not supported at an altitude of
over 3000 m (9842.5 ft).
RH8100 V3 Server
User Guide 2 About the RH8100 V3
Issue 30 (2019-12-19) Copyright © Huawei Technologies Co., Ltd. 76

Table of Contents