How the Plasma Power Supply Operates
7
166 810430 Troubleshooting Guide Powermax65/85/105 SYNC
Figure 47 – 200 V 600 V CSA plasma power supply (power PCB removed)
7
8
9
1
2
3
45
6
11
13
12
1
0
1 Output snubber resistor
2 Output diode bridge
3 Pilot arc IGBT
4 Inverter snubber resistor
5 Inverter IGBT module
6 Bulk capacitor
7 PFC snubber resistor
8 PFC IGBT module
9 Damper resistor
10 Ground
11 Input diode bridge
12 Power switch (S1)
13 Optional serial PCB

Table of Contents