Troubleshooting for Fault Codes
54 810430 Troubleshooting Guide Powermax65/85/105 SYNC
0-60-1
Yellow
Yellow
An AC input voltage is too
low.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
• The input line voltage is too low (more than
15% below the rated voltage). Have an
electrical technician examine the line and
increase the voltage.
• If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
•Do Test 1 – Voltage input on page 78.
• This fault code is not applicable for
Powermax65/85 SYNC CSA models.
0-60-2
Yellow
Yellow
An AC input voltage is too
high.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
• The input line voltage is too high (more than
10% above the rated voltage). Have an
electrical technician examine the line and
decrease the voltage.
• If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
•Do Test 1 – Voltage input on page 78.
• This fault code is not applicable for
Powermax65/85 SYNC CSA models.
0-61-0
Yellow
Yellow
An AC input is not stable.
Shut down the system.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
• The current from the incoming power line is
unstable. Stop power to the system and
correct the line resonance problem before
continuing.
• If possible, connect the system to a different
AC power source.
• Make sure that the plasma power supply is
not being used on a phase converter.
• If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
• This fault code is not applicable for
Powermax65/85 SYNC CSA models.
Fault
code
Fault
icon
Fault
LEDs Description Solutions