Troubleshooting for Fault Codes
3
54 810430 Troubleshooting Guide Powermax65/85/105 SYNC
0-60-1
Yellow
Yellow
An AC input voltage is too
low.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
The input line voltage is too low (more than
15% below the rated voltage). Have an
electrical technician examine the line and
increase the voltage.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
•Do Test 1 – Voltage input on page 78.
This fault code is not applicable for
Powermax65/85 SYNC CSA models.
0-60-2
Yellow
Yellow
An AC input voltage is too
high.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
The input line voltage is too high (more than
10% above the rated voltage). Have an
electrical technician examine the line and
decrease the voltage.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
•Do Test 1 – Voltage input on page 78.
This fault code is not applicable for
Powermax65/85 SYNC CSA models.
0-61-0
Yellow
Yellow
An AC input is not stable.
Shut down the system.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
The current from the incoming power line is
unstable. Stop power to the system and
correct the line resonance problem before
continuing.
If possible, connect the system to a different
AC power source.
Make sure that the plasma power supply is
not being used on a phase converter.
If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
This fault code is not applicable for
Powermax65/85 SYNC CSA models.
Fault
code
Fault
icon
Fault
LEDs Description Solutions

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals