Troubleshooting for Fault Codes
Powermax65/85/105 SYNC Troubleshooting Guide 810430 53
0-51-0
Yellow
Yellow
The plasma power supply
was receiving a signal to start
cutting at the same time that
the power switch was set to
ON (I).
With a machine torch, this
condition is sometimes
referred to as a “stuck start.”
This fault code stops the system from operating.
Do the following. A quick restart is necessary.
• Hand torch: The torch trigger was being
held in the “fire” position when the power
switch on the plasma power supply was set
to ON (I). Release the trigger and do a
quick restart of the plasma power supply.
• Machine torch: The plasma power supply
was receiving a Start signal when the power
switch was set to ON (I). Set the Start
signal to off, and do a quick restart of the
plasma power supply.
• If possible, do a test with a different torch
that is known to operate correctly.
•Do Test 7 – Start signal on page 102.
0-52-0
Yellow
Yellow
The torch is not connected. This fault code stops the system from operating.
Do the following. A quick restart is necessary.
• Make sure that the torch lead is correctly
connected to the FastConnect receptacle
on the front of the plasma power supply. Do
a quick restart.
• Do a check for continuity at the
FastConnect receptacle. Refer to page 25.
• If you disconnect the torch while the plasma
power supply is set to ON (I), you get the
0-52-0 fault code.
• If you disconnect the torch while the plasma
power supply is set to OFF (O), you get the
0-50-0 fault code the next time you set the
plasma power supply to ON (I).
0-60-0
Yellow
Yellow
An AC input voltage phase
loss occurred.
This is applicable only to CE
models and to
Powermax105 SYNC CSA
models.
This fault code stops the system from operating.
Do the following. A cold restart is necessary.
• Have an electrical technician examine all
input phases and fuses/breakers for correct
voltage at the power source and at the
plasma power supply.
• If applicable, disconnect the system from
generator power, or set the generator mode
feature to on. Refer to Generator
considerations on page 62.
•Do Test 1 – Voltage input on page 78.
Fault
code
Fault
icon
Fault
LEDs Description Solutions