EasyManuals Logo

Hypertherm Powermax65 SYNC Troubleshooting Guide

Hypertherm Powermax65 SYNC
180 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #71 background imageLoading...
Page #71 background image
Troubleshooting for Common Problems
4
Powermax65/85/105 SYNC Troubleshooting Guide 810430 71
The system
changes the gas
pressure after you
set it manually.
The manual gas
pressure mode gets
overridden in some
conditions.
The following conditions
cause the system to override
a manual gas pressure
setting with the default gas
pressure setting that matches
the type of cartridge installed
on the torch:
Install a different type of
cartridge.
Adjust the gas pressure
while the torch is locked
and then unlock the
torch.
Go back to manual gas pressure
mode, and set the gas pressure
again. Make sure that the torch is
unlocked before you set the gas
pressure.
The system
changes the
output current (A)
or the operating
mode after you
set them.
You changed those
settings while the
torch was locked.
The system does not
keep changes to the
output current (A) or
operating mode while the
torch-lock switch is in the
yellow lock (X) position
or while there is an
0-50-n “cartridge off”
fault condition.
Set the torch-lock switch to the
“ready to fire” ( ) position before
you adjust the amperage or
operating mode.
When you set the torch-lock switch
to the “ready to fire” ( ) position,
the system automatically sets the
amperage and operating mode to
match the type of cartridge installed
on the torch.
The LCD screen
shows a
FACTORY
RESET?
message when
you try to go to
the service
screens.
You pushed the
incorrect buttons on
the front panel.
•The FACTORY RESET?
message shows when
you push and hold
and for
approximately 2 seconds.
To get out of the FACTORY RES ET?
message, make sure that the Cancel
button is selected, and push .
This sends you back to the screen
you were on without making
changes. Refer to Set system
settings to factory default on
page 156.
To go to the service screens, push
and hold for 2 seconds.
Problem Meaning Causes Solutions

Table of Contents

Other manuals for Hypertherm Powermax65 SYNC

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax65 SYNC and is the answer not in the manual?

Hypertherm Powermax65 SYNC Specifications

General IconGeneral
BrandHypertherm
ModelPowermax65 SYNC
CategoryWelding System
LanguageEnglish

Related product manuals