275
Part 2 Startu
p
Cha
p
te
r
Setting Range
RS485SIO
Network Type CC-Link DeviceNet PROFIBUS
Modbus gateway
mode
SIO through
mode
[7] Address Desired value from 1
to 64
(Normally the master
unit has address 0.)
Desired value
from 0 to 63
(Normally the
master unit has
address 63.)
Desired value
from 1 to 125
63 (fixed)
-
[8] Baud rate 156 Kbps
635 Kbps
2.5 Mbps
5 Mbps
10 Mbps
Auto Auto 9.6 Kbps
19.2 Kbps
38.4 Kbps
57.6 Kbps
115.2 Kbps
230.4 Kbps
38.4 Kbps
57.6 Kbps
115.2 Kbps
230.4 Kbps
[10] Displayed
occupancy
information
I/O size (bytes)
-
Number of (positioner 1/simple direct mode) axes
× 8 +
Number of direct numerical specification (positioning)
mode axes
× 16 + 16
Or,
Number of positioner 2 mode axes
× 4.
-