• Airow Out–Air enters the switch through the vents in the port panel.
All EX4600 switches, except the EX4600-40F-S, are shipped with ve fan modules and two power
supplies. Order fans for the EX4600-40F-S separately.
CAUTION: Do not mix:
• AC and DC power supplies in the same chassis.
• Power supplies with dierent airow labels (AFI) and (AFO) in the same chassis.
• Fan modules with dierent airow labels (AIR INI) and (AIR OUT) in the same
chassis.
• Power supplies and fan modules with dierent airow labels (AIR INI) and AIR OUT)
or AFI and AFOin the same chassis.
Fan Modules
The fan modules in EX4600 switches are hot-insertable and hot-removable eld-replaceable units
(FRUs). These fan modules are designed for one of the two available airow direcons airow in (AIR IN)
or airow out (AIR IN)) and are the same fan modules used in the QFX5100 switches. Some modules are
also color-coded for the indicaon of the airow direcon. The fan modules are installed in the fan
module slots on the FRU end of the switch, next to the power supplies. The fan module slots are
numbered 0 through 4 from le to right. Each slot has a fan icon next to it.
Figure 12 on page 22 shows the fan module for the EX4600 switch.
Figure 12: Fan Module for EX4600 Switches
22