Table 35: PTX10001-36MR System Alarm Messages
(Connued)
Component Alarm Type CLI Message Recommended Acon
sensor-location
Temp Sensor Too Hot
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor. If the condion
persists, the device might shut
down.
Minor (yellow)
sensor-location
Temp Sensor Too
Warm
For informaon only. Check
environmental condions and
alarms on other devices. Ensure that
environmental factors (such as hot
air blowing around the equipment)
do not aect the temperature
sensor.
Roung Engine Major (red)
RE
RE number
/var partition is full
Clean up the system le storage
space on the device. For more
informaon, see
request system
storage cleanup
.
Minor (yellow)
RE
RE number
/var partition usage
is high
Clean up the system le storage
space on the device. For more
informaon, see
request system
storage cleanup
.
132