Table 35: PTX10001-36MR System Alarm Messages
(Connued)
Component Alarm Type CLI Message Recommended Acon
sensor-location
Temp Sensor Too Hot
Check environmental condions
and alarms on other devices. Ensure
that environmental factors (such as
hot air blowing around the
equipment) do not aect the
temperature sensor. If the condion
persists, the device might shut
down.
Minor (yellow)
sensor-location
Temp Sensor Too
Warm
For informaon only. Check
environmental condions and
alarms on other devices. Ensure that
environmental factors (such as hot
air blowing around the equipment)
do not aect the temperature
sensor.
Roung Engine Major (red)
RE
RE number
/var partition is full
Clean up the system le storage
space on the device. For more
informaon, see
request system
storage cleanup
.
Minor (yellow)
RE
RE number
/var partition usage
is high
Clean up the system le storage
space on the device. For more
informaon, see
request system
storage cleanup
.
132