WARNING: Ensure that the power cord does not block access to router components
or drape where people could trip on it.
4. Connect each power supply to the power sources. Insert the coupler end of the power cord into the
AC power cord inlet on the AC power supply faceplate (see Figure 31 on page 89).
NOTE: The coupler end of the power cord model is APP-400.
Figure 31: Connect an AC Power Cord to the PTX10001-36MR
5. If the AC power source outlet has a power switch, set it to the o (O) posion.
NOTE: The device powers on as soon as power is provided to the power supply. There is no
power switch on the device.
6. Insert the power cord plug into an AC power source outlet.
7. If the AC power source outlet has a power switch, set it to the on (|) posion.
8. Verify that the status LEDs on each power supply are lit green.
If the status LED is lit amber, remove power from the power supply, and replace the power supply
(see "Maintain the PTX10001-36MR Power Supplies" on page 108). Do not remove the power supply
unl you have a replacement power supply ready.
CAUTION: Replace a failed power supply with a new power supply within 2 minutes of
removal to prevent chassis overheang.
89