Keyscan Inc. A Member of the Kaba Group – CA150 Rev. B Installation Guide (07.15)
Table 17 – CA150B Quick Reference
Maximum current load for all
devices = 680 mA
12 VDC – Power In (+) & (-)
terminals
Resets board to factory defaults
S1.1 to S1.12 – System
Configuration
For communication and system
settings
S2.1 to S2.6 – Reader
Configuration
Sets system to specific reader
format/type
S2.7 to S2.8 – Supervision
Mode
Sets the input supervision type
S2.9 to S2.10 – System
Software Mode
Sets the board for the Keyscan
system software application
Resets the control board to affect
communication or jumper
changes
J8 to J9 – Door Output Relay
Powered/Unpowered
Sets Door relay with power from
control board or as a dry contact
J10 to J11 – Aux Output
Relay Powered/Unpowered
Sets Aux relay with power from
control board or as a dry contact
10s counts first binary digit
1s counts the second binary digit
For direct RS-232 serial
communication, connect to RS-
232 (TB5) terminal block
S1.10 & S1.11 – switches OFF
Ethernet - Operation Mode
(Network TCP/IP)
For network communication,
connect network cable to on-
board Ethernet terminal
S1.10 – switch ON / S1.11 –
switch OFF
Ethernet - Program Mode
(Network TCP/IP)
Ethernet program mode uses RS-
232 via TB5 at 9600 BPS.
S1.10 – Switch ON / S1.11 –
switch ON
Control Board Test
Voltages
Communication Test
Voltages