4
LeeBoy 6150 Conveyor Paver 4-15
Operation
Regen Level 3: The rst Level 3 screen is the warning.
(Figure 4-32) Urgent: Engine output limited. The DPF
is EXTREMELY loaded with soot and needs to be regen-
erated.
Figure 4-32. Regen Level 3 Warning
Use the DOWN arrow to scroll to the second Regen
Level 3 message that contains instructions for perform-
ing needed regeneration (Figure 4-33):
1. Move the machine to a safe location.
2. Place in Park or Neutral.
3. Set the engine to low idle.
4. Uninhibit regeneration.
5. Apply the parking brake (if equipped).
Figure 4-33. Secondary Regen Level 3 Notice
Regen Level 2: The rst Level 2 screen is the warning.
(Figure 4-30) The DPF is loaded with soot and needs
to be regenerated. When safe either uninhibit automatic
active regeneration or complete a parked regeneration.
Figure 4-30. Regen Level 2 Notice
Use the DOWN arrow to scroll to the second Regen
Level 2 message that contains instructions for perform-
ing needed regeneration (Figure 4-31):
1. Move the machine to a safe location.
2. Place in Park or Neutral.
3. Set the engine to low idle.
4. Uninhibit regeneration.
5. Apply the parking brake (if equipped).
Figure 4-31. Secondary Regen Level 2 Notice