LeeBoy 8510E Conveyor Paver 4-15
Operation
If the operator does not wish to complete a Parked
Regeneration, click the soft key. This action
cancels Regen, removes the pop-up message, and
takes the operator back to the Gauge Screen.
NOTE: The machine must be in park and neutral with
a DPF level of 2 or higher to preform Parked
Regeneration.
EXHAUST TEMPERATURES WILL BE
EXTREMELY HIGH. BE SURE EXHAUST WILL NOT
COME IN CONTACT WITH ANY COMBUSTIBLE
MATERIALS.
If you want to perform regen:
• Ensure the machine is in neutral and parking brake
applied. The coolant temperature must be in
operating range (typically 155° -1 60 F°). Set the
engine to low idle.
• Once these conditions are met, a blue screen
message will appear. (Figures 4-25 to 4-26).
• Using the Up/Down Arrow, scroll down through the
entire message and press the Request Regen Button.
Figure 4-25. Parked Regeneration Blue Screen
Some messages require using the UP/DOWN soft keys
to maneuver through the entire message (Figures 4-23
and 4-24).
Figure 4-23. Regen Caution Message Popup Screen
Example Requiring Use of UP/DOWN Soft Keys
Figure 4-24. Parked Regeneration Instructions
Screen