What to do if the auger is not turning properly on LeeBoy Construction Equipment?
M
Mallory GreeneSep 3, 2025
If the auger on your LeeBoy Construction Equipment is not turning properly, several factors could be at play. The drive chain might be too loose, requiring adjustment, or it could be broken, necessitating replacement. A faulty motor or a defective solenoid valve could also be the cause, both requiring replacement. Additionally, asphalt buildup can hinder performance, so clean thoroughly and grease the area. Finally, an overload of material to the augers can cause issues; set the conveyor to the proper speed in AUTO or use paddles in MANUAL position.
N
norma24Sep 1, 2025
What causes LeeBoy Construction Equipment machine to not pull on one or both sides?
O
Olivia GarrettSep 2, 2025
If your LeeBoy Construction Equipment machine will not pull on one or both sides, it could be due to a faulty hydraulic motor, which would need to be replaced. It could also be due to pump pressure being too low, so check the pump pressure and relieve or adjust it. Another cause could be a faulty torque hub, which may need to be rebuilt or replaced.
K
Kenneth ConnerAug 31, 2025
Why LeeBoy Construction Equipment machine does not steer straight?
C
Christina NielsenAug 31, 2025
If your LeeBoy Construction Equipment machine does not steer straight, it could be due to several reasons. One of the hydraulic drive motors might need adjustment, so readjust the motor(s). The steering control might not be centered, so center the steering control. Alternatively, the travel pump could be defective, requiring replacement or rebuilding.
R
Regina NorrisAug 29, 2025
What to check if LeeBoy Construction Equipment machine will not move?
P
pwarnerAug 29, 2025
If your LeeBoy Construction Equipment machine will not move, check the RUN/STOP switch for any faults.
S
sherryallenAug 27, 2025
Why electric screed heating system will not operate on LeeBoy Construction Equipment?
A
Albert GarciaAug 28, 2025
If the electric screed heating system of your LeeBoy Construction Equipment will not operate, first ensure that the screed operator control box power switch is in the ON position. Also, check that all element breakers are in the proper set position and not in a tripped position. Finally, verify that the generator is spinning and check its voltage and frequency; rebuild or replace the generator if needed.
N
ndavilaAug 26, 2025
What to do if LeeBoy Construction Equipment engine turns over but does not start?
C
Christopher MorrisAug 26, 2025
If the engine turns over but doesn't start in your LeeBoy Construction Equipment, the issue might be due to low fuel. In this case, add fuel to the fuel tank. Alternatively, it could be a low battery, which may require replacement or rebuilding. Finally, check the indicator light bulb and replace it if it's bad.
M
Michele RodriguezAug 25, 2025
What to do if the electric screed heat system doesn’t start, or starts and doesn’t run very long on LeeBoy Construction Equipment?
J
John MeyersAug 25, 2025
If the electric screed heat system on your LeeBoy Construction Equipment doesn’t start, or starts and doesn’t run very long, the heating system may have timed out. Check the timing relay and adjust or replace it as needed.
M
Matthew OlsonAug 23, 2025
How to troubleshoot a LeeBoy Construction Equipment engine that won't start?
C
Courtney RomanAug 23, 2025
If your LeeBoy Construction Equipment engine won't start, there are several potential causes. First, check if the battery is defective or has a low charge; if so, replace or charge it. Ensure the master switch is in the ON position. Verify there's sufficient fuel. A faulty safety switch, solenoid, neutral switch, or engine starter relay could also be the culprit, so consider replacing them as needed. Also, check if the switch box is unplugged and replug it. Finally, make sure the E-Stop is disengaged.