EasyManua.ls Logo

Lenovo System x3650 M5 - Microprocessor Problems

Lenovo System x3650 M5
1340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
FollowthesuggestedactionsintheorderinwhichtheyarelistedintheActioncolumnuntiltheproblemis
solved.
Ifanactionstepisprecededby“(Trainedtechnicianonly),thatstepmustbeperformedonlybyatrained
technician.
Gotothesupportwebsiteathttp://www.lenovo.com/supporttocheckfortechnicalinformation,hints,tips,
andnewdevicedriversortosubmitarequestforinformation.
SymptomAction
Thereisnomemorymismatchwhentheserverisattheminimummemory
configuration.
2.ReseattheDIMMs,andthenrestarttheserver.
3.CheckthePOSTerrorlog:
IfaDIMMwasdisabledbyasystems-managementinterrupt(SMI),replace
theDIMM.
IfaDIMMwasdisabledbytheuserorbyPOST,reseattheDIMM;then,run
theSetupUtilityandenabletheDIMM.
4.CheckthatallDIMMsareinitializedintheSetupUtility;then,runmemory
diagnostics(see“RunningtheDSAPrebootdiagnosticprograms”onpage82).
5.ReversetheDIMMsbetweenthechannels(ofthesamemicroprocessor),and
thenrestarttheserver.IftheproblemisrelatedtoaDIMM,replacethefailing
DIMM.
6.Re-enableallDIMMsusingtheSetupUtility,andthenrestarttheserver.
7.(Trainedtechnicianonly)InstallthefailingDIMMintoaDIMMconnector
formicroprocessor2(ifinstalled)toverifythattheproblemisnotthe
microprocessorortheDIMMconnector.
8.(Trainedtechnicianonly)Replacethesystemboard.
MultipleDIMMsinachannel
areidentifiedasfailing.
Note:EachtimeyouinstallorremoveaDIMM,youmustdisconnecttheserverfrom
thepowersource;then,wait10secondsbeforerestartingtheserver.
1.ReseattheDIMMs;then,restarttheserver.
2.Removethehighest-numberedDIMMofthosethatareidentifiedandreplace
itwithanidenticalknowngoodDIMM;then,restarttheserver.Repeatas
necessary.IfthefailurescontinueafterallidentifiedDIMMsarereplaced,go
tostep4.
3.ReturntheremovedDIMMs,oneatatime,totheiroriginalconnectors,restarting
theserveraftereachDIMM,untilaDIMMfails.ReplaceeachfailingDIMM
withanidenticalknowngoodDIMM,restartingtheserveraftereachDIMM
replacement.Repeatstep3untilyouhavetestedallremovedDIMMs.
4.Replacethehighest-numberedDIMMofthoseidentified;then,restartthe
server.Repeatasnecessary.
5.ReversetheDIMMsbetweenthechannels(ofthesamemicroprocessor),and
thenrestarttheserver.IftheproblemisrelatedtoaDIMM,replacethefailing
DIMM.
6.(Trainedtechnicianonly)InstallthefailingDIMMintoaDIMMconnector
formicroprocessor2(ifinstalled)toverifythattheproblemisnotthe
microprocessorortheDIMMconnector.
7.(Trainedtechnicianonly)Replacethesystemboard.
Microprocessorproblems
Usethetroubleshootingtablestofindsolutionstoproblemsthathaveidentifiablesymptoms.
Chapter3.Troubleshooting89

Table of Contents

Other manuals for Lenovo System x3650 M5

Related product manuals