SAS signal cable
Power / configuration
cable
Figure271.8x2.5-inchsimple-swapharddiskdrivewithhardwareRAIDcabling
Step9.Replacethefancageassemblyandfansifyouremovedthem(see“Replacingthefancage
assembly”onpage179
and“Replacingahot-swapfan”onpage181).
Step10.Reinstalltheharddiskdrives(see“Replacingahot-swapharddiskdrive”onpage159).
Step11.Installthetopcover(see“Replacingthetopcover”onpage151).
Step12.Slidetheserverintotherack.
Step13.Reconnectthepowercordsandanycablesthatyouremoved.
Step14.Turnontheperipheraldevicesandtheserver.
Installinga8x3.5-inchsimple-swapHDDServeRAIDassemblykit
Usethisinformationtoinstalla8x3.5-inchsimple-swapHDDServeRAIDassemblykit.
YoucaninstallaLenovoSystemx3650M58x3.5-inchsimple-swapHDDServeRAIDassemblykitto
supporteight3.5-inchsimple-swapharddiskdrivemodelintheserver.Seehttp://www.lenovo.com/
serverproven/foralistofsupportedoptionaldevices.Toordera8x3.5-inchhot-swapHDDassembly
kit,contactyoursalesrepresentativeorreseller.
The8x3.5-inchsimple-swapHDDServeRAIDassemblykitcontainsonesimple-swapbackplateassembly
withtwocablesattached.
Toinstalla8x3.5-inchhot-swapHDDassemblykit,completethefollowingsteps:
302LenovoSystemx3650M5InstallationandServiceGuide