Security bezel
2
1
Figure237.Securitybezelinstallation
Step4.Usethekeytolockthebezelifrequired.
RemovinganoptionalServeRAIDadaptermemorymodule
UsethisinformationtoremoveanoptionalServeRAIDadaptermemorymodule.
ToremoveanoptionalServeRAIDadaptermemorymodule,completethefollowingsteps.
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page297.
Step2.Turnofftheserver,anddisconnectallpowercordsandexternalcables.
Step3.Removethetopcover(see“Removingthetopcover”onpage149).
Step4.LocatetheServeRAIDadapterwiththeServeRAIDadaptermemorymoduleinstalled.Thenremove
anypartsanddisconnectanycablesthatmightimpedeyouraccesstotheServeRAIDadapter
memorymodule.
Step5.Pivottheretainingclipsoutward.ThengrasptheServeRAIDadaptermemorymodulebyitsedges
andcarefullypullitstraightuptoremoveitfromthememorymoduleslotontheServeRAIDadapter.
Figure238.ServeRAIDadaptermemorymoduleremoval
Step6.IfyouareinstructedtoreturntheServeRAIDadaptermemorymodule,followallpackaging
instructions,anduseanypackagingmaterialsforshippingthataresuppliedtoyou.
274LenovoSystemx3650M5InstallationandServiceGuide