Hot-swap
power supply 2
Power supply
filler panel
Figure195.Powersupplyremoval
Step5.Ifyouareinstructedtoreturnthepowersupply,followallpackaginginstructions,anduseany
packagingmaterialsforshippingthataresuppliedtoyou.
Replacingahot-swapacpowersupply
Usethisinformationtoreplaceahot-swapacpowersupply.
Thefollowingnotesdescribethetypeofpowersupplythattheserversupportsandotherinformationthat
youmustconsiderwhenyouinstallapowersupply:
•Beforeyouinstallanadditionalpowersupplyorreplaceapowersupplywithoneofadifferentwattage,
youmayusethePowerConfiguratorutilitytodeterminecurrentsystempowerconsumption.Formore
informationandtodownloadtheutility,gotohttp://www.ibm.com/systems/bladecenter/resources/
powerconfig.html.
•Theservercomeswithonehot-swap12-voltoutputpowersupplythatconnectstopowersupplybay1.
Theinputvoltageis100-127Vacor200-240Vacauto-sensingforACpowersuppliedandis-48Vdc
or-60Vdcauto-sensingforDCpowersupplies.
•Powersuppliesintheservermustbewiththesamepowerratingorwattage,andthesame80-plus
efficiencyleveltoensurethattheserverwilloperatecorrectly.Forexample,youcannotmix550-watt
and750-wattpowersuppliesintheserver.Moreover,youcannotmix750-wattPlatinumand750-watt
Titaniumsuppliesintheserver.
•Powersupply1isthedefault/primarypowersupply.Ifpowersupply1fails,youmustreplacethepower
supplywiththesamewattageandthesame80-plusefficiencylevelimmediately.
•Youcanorderanoptionalpowersupplyforredundancy.
•Thesepowersuppliesaredesignedforparalleloperation.Intheeventofapower-supplyfailure,the
redundantpowersupplycontinuestopowerthesystem.Theserversupportsamaximumoftwo
powersupplies.
Statement5