Step4.Removethereartwohard-disk-drivekitthatcontainstheadapter(see“Removingthereartwo
hard-disk-drivekit”onpage207
).
•IfyouareremovinganadapterfromPCIexpansionslot3,removereartwohard-disk-drivekit1.
•IfyouareremovinganadapterfromPCIexpansionslot8,removereartwohard-disk-drivekit2.
Step5.Disconnectanycablesfromtheadapter(makenoteofthecablerouting,incaseyoureinstall
theadapterlater).
Step6.1Slidetheretentionbracket;then,2rotateittotheopenposition.
1
3
2
Adapter
Adapter connector
Bracket
Rear two hard-disk-drive kit
Figure130.Adapterremoval
Step7.Removethescrewsifpresent.Thesescrewscanbefastenedtothesideoftheriser-cardassembly
forstorageifneeded.
Step8.3Carefullygrasptheadapterbyitstopedgeoruppercorners,andpulltheadapteroutofthe
reartwohard-disk-drivekit.
Step9.Ifyouareinstructedtoreturntheadapter,followallpackaginginstructions,anduseanypackaging
materialsforshippingthataresuppliedtoyou.
Replacinganadapter
Usethisinformationtoreplaceanadapter.
Notes:
•Ifyouradapterwaspreviouslyconfigured,backuporrecorditsconfigurationinformation,ifpossible,
beforereplacingtheadapter.Seethedocumentationforyouradapterforinformationandinstructions.
•IfyouarereplacingaServeRAIDadapter,importyourRAIDconfigurationtothereplacementadapteras
aforeignconfigurationafteryoufinishthereplacement.SeetheServeRAID-MSoftwareUserGuideat
https://support.lenovo.com/us/en/documents/migr-5086126forinstructions.
•Thefollowingadapterssupport10-Gbpstransferrateonly:
–IntelX7102x10GbESFP+Adapter
–IntelX710ML24x10GbESFP+Adapter
–IntelX710-DA2ML22x10GbESFP+Adapter
Replacinganadapterinariser-cardassembly
Usethissectiontoreplaceanadapterinariser-cardassembly.
196LenovoSystemx3650M5InstallationandServiceGuide