Fan 1
Fan 2
Fan 3
Fan 4
Fan 5
Fan 6
Fan latch
Hot-swap
fan error LED
1
2
Figure110.Fanremoval
Attention:Toensureproperoperation,replaceafailedhot-swapfanwithin30seconds.
Step4.Ifyouareinstructedtoreturnthefan,followallofthepackaginginstructions,anduseany
packagingmaterialsforshippingthataresuppliedtoyou.
Replacingahot-swapfan
Usethisinformationtoreplaceahot-swapfan.
Forpropercooling,theserverrequiresthatallfourhot-swapfansbeinstalledatalltimes.
Attention:Toensureproperoperation,replaceafailedhot-swapfanwithin30seconds.
Toreplaceahot-swapfan,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page297.
Step2.Removethetopcover(see“Removingthetopcover”onpage149).
Step3.Touchthestatic-protectivepackagethatcontainsthenewfantoanyunpaintedmetalsurfaceon
theserver.Then,removethenewfanfromthepackage.
Step4.Orientthefanoverthefanslotinthefancagesothatthefanconnectoralignswiththeconnector
onthesystemboard.
Step5.Insertthefanintothefanslotinthefancageandpressitdownuntilitisseatedcorrectlyintheslot.
Chapter5.Installing,removing,andreplacingcomponents181