Filler panel
3.5-inch simple-swap
hard disk drive
Figure94.3.5-inchsimple-swapharddiskdriveinstallation
Step6.Reinstallthedrivebayfillerpanelthatyouremovedearlier,ifneeded.
Step7.Ifyouareinstallingadditionalsimple-swapharddiskdrives,dosonow.
Step8.Turnontheperipheraldevicesandtheserver.
Removingtheopticaldrivecable
Usethisinformationtoremovetheopticaldrivecable.
Note:Theopticaldriveisavailableonlyonsomemodels.
Toremovetheopticalcable,completethefollowingsteps:
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page297.
Step2.Turnofftheserverandperipheraldevicesanddisconnectthepowercords.
Step3.Removethetopcover(see“Removingthetopcover”onpage149).
Step4.Removethefancageassembly(see“Removingthefancageassembly”onpage178).
Step5.Pulltheconnectortowardthefrontoftheservertoremovetheopticaldrivecablefromthe
connectoronthesystemboard.