ReplacinganoptionalServeRAIDadaptermemorymodule
UsethisinformationtoreplaceanoptionalServeRAIDadaptermemorymodule.
ToreplaceanoptionalServeRAIDadaptermemorymodule,completethefollowingsteps.
Step1.Readthesafetyinformationthatbeginson“Safety”onpagevand“Installationguidelines”on
page297
.
Step2.Turnofftheserver,anddisconnectallpowercordsandexternalcables.
Step3.Removethetopcover(see“Removingthetopcover”onpage149).
Step4.LocatetheServeRAIDadapterontowhichyouwanttoinstalltheServeRAIDadaptermemory
module.Thenremoveanypartsanddisconnectanycablesthatmightimpedeyouraccesstothe
ServeRAIDadapter.
Step5.Touchthestatic-protectivepackagethatcontainstheServeRAIDadaptermemorymoduletoany
unpaintedmetalsurfaceontheserver.ThenremovetheServeRAIDadaptermemorymodule
fromthepackage.
Step6.AligntheServeRAIDadaptermemorymodulewiththememorymoduleslotontheServeRAID
adapter.Thenpressthememorymodulestraightdownintotheslotuntilthememorymodule
snapsintoposition.Ensurethatthememorymoduleisfirmlyseated.
ServeRAID adapter
memory module
ServeRAID adapter
memory module slot
Retention
bracket
ServeRAID adapter
Figure239.ServeRAIDadaptermemorymoduleinstallation
Step7.Reinstallanypartsandreconnectanycables.Thenreinstallthetopcover(see“Replacingthetop
cover”onpage151).
Step8.Slidetheserverintotherack.
Step9.Reconnectthepowercordsandallexternalcables,andturnontheserverandperipheraldevices.
RemovingandreplacingTier2CRUs
YoumayinstallaTier2CRUyourselforrequestLenovotoinstallit,atnoadditionalcharge,underthetype
ofwarrantyservicethatisdesignatedforyourserver.
Theillustrationsinthisdocumentmightdifferslightlyfromyourhardware.
Chapter5.Installing,removing,andreplacingcomponents275