EasyManua.ls Logo

Lenovo System x3650 M5 - Running the Dsa Preboot Diagnostic Programs; Diagnostic Text Messages

Lenovo System x3650 M5
1340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Checkpointpanel
I2Cbus
SASandSATAdrives
Ifyouareabletorestarttheserverorifyouneedcomprehensivediagnostics,useDSAPreboot.
Formoreinformationandtodownloadtheutilities,gotohttps://support.lenovo.com/us/
en/documents/LNVO-DSA.
RunningtheDSAPrebootdiagnosticprograms
UsethisinformationtoruntheDSAPrebootdiagnosticprograms.
Note:TheDSAmemorytestmighttakeupto30minutestorun.Iftheproblemisnotamemoryproblem,
skipthememorytest.
ToruntheDSAPrebootdiagnosticprograms,completethefollowingsteps:
Step1.Iftheserverisrunning,turnofftheserverandallattacheddevices.
Step2.Turnonallattacheddevices;then,turnontheserver.
Step3.Whentheprompt<F2>Diagnosticsisdisplayed,pressF2.
Note:TheDSAPrebootdiagnosticprogrammightappeartobeunresponsiveforanunusual
lengthoftimewhenyoustarttheprogram.Thisisnormaloperationwhiletheprogramloads.The
loadingprocessmaytakeupto10minutes.
Step4.Optionally,selectQuittoDSAtoexitfromthestand-alonememorydiagnosticprogram.
Note:Afteryouexitfromthestand-alonememorydiagnosticenvironment,youmustrestartthe
servertoaccessthestand-alonememorydiagnosticenvironmentagain.
Step5.Typeguitodisplaythegraphicaluserinterface,ortypecmdtodisplaytheDSAinteractivemenu.
Step6.Followtheinstructionsonthescreentoselectthediagnostictesttorun.
Ifthediagnosticprogramsdonotdetectanyhardwareerrorsbuttheproblemremainsduringnormalserver
operation,asoftwareerrormightbethecause.Ifyoususpectasoftwareproblem,seetheinformation
thatcomeswithyoursoftware.
Asingleproblemmightcausemorethanoneerrormessage.Whenthishappens,correctthecauseofthe
firsterrormessage.Theothererrormessagesusuallywillnotoccurthenexttimeyourunthediagnostic
programs.
Iftheserverstopsduringtestingandyoucannotcontinue,restarttheserverandtryrunningtheDSA
Prebootdiagnosticprogramsagain.Iftheproblemremains,replacethecomponentthatwasbeingtested
whentheserverstopped.
Diagnostictextmessages
Diagnostictextmessagesaredisplayedwhilethetestsarerunning.
Adiagnostictextmessagecontainsoneofthefollowingresults:
Passed:Thetestwascompletedwithoutanyerrors.
Failed:Thetestdetectedanerror.
82LenovoSystemx3650M5InstallationandServiceGuide