Completethefollowingsteps:
1.Informationonly;noactionisrequired.
•I.580A4Memorypopulationchangedetected.DIMMPopulationChangeDetected
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.IfyouhaveaddedorremovedDIMMstothesystem,andnoadditionalerrorsweredetected,
thenpleaseignorethismessage.
2.ChecksystemeventlogforuncorrectedDIMMfailuresandreplacethoseDIMMs.
•I.580A5MirrorFail-overcomplete.DIMMnumber[arg1]hasfailedovertotothemirroredcopy.
DIMMMirrorFail-overDetected
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.Checkthesystem-eventlogforuncorrectedDIMMfailuresandreplacethoseDIMMs.
•I.580A6Memorysparecopyhascompletedsuccessfully.SpareCopyComplete
Explanation:
Severity
Info
UserResponse
Completethefollowingsteps:
1.IfyouhaveaddedorremovedDIMMstothesystem,andnoadditionalerrorsweredetected,
thenpleaseignorethismessage.
2.ChecksystemeventlogforuncorrectedDIMMfailuresandreplacethoseDIMMs.
•S.1100BCATERR(IERR)hasassertedonprocessor[arg1].ProcessorCATERR(IERR)hasasserted
Explanation:
Severity
Error
UserResponse
Completethefollowingsteps: