Loading...
Severity
Warning
Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
405-900-000:BRCM:T estControlRegistersTestFailed
AfailurewasdetectedwhiletestinginternalMACregisters
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
2.Rerunthetest.
3.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
405-901-000:BRCM:TestMIIRegistersTestFailed
AfailurewasdetectedwhiletestinginternalPHYregisters.
Recoverable
No
Severity
Error
Serviceable
Yes