EasyManua.ls Logo

Lenovo System x3650 M5 - Page 1190

Lenovo System x3650 M5
1340 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Serviceable
No
Automaticallynotifysupport
No
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
516-900-000:ELXUCNA:NICMACLoopBackTestFailed
AfailurewasdetectedduringtheloopbacktestattheMAClayer.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
UserResponse
Completethefollowingsteps:
1.Checkcomponentfirmwarelevelandupgradeifnecessary.Theinstalledfirmwarelevelcanbe
foundintheDSADiagnosticEventLogwithintheFirmware/VPDsectionforthiscomponent.
2.Rerunthetest.
3.Iffailureremains,referto"Troubleshootingbysymptom"inthesystem"InstallationandService
Guide"forthenextcorrectiveaction.
Relatedlinks
LenovoSupportwebsite
LatestlevelofDSA
LatestlevelofBMC/IMM
516-901-000:ELXUCNA:NICPHYLoopBackTestFailed
Afailurewasdetectedduringtheloopbacktestatthephysicallayer.
Recoverable
No
Severity
Error
Serviceable
Yes
Automaticallynotifysupport
No
1178LenovoSystemx3650M5InstallationandServiceGuide

Table of Contents

Other manuals for Lenovo System x3650 M5

Related product manuals