Theservercomeswithanintegrateddual-portIntelGigabitEthernetcontroller,whichsupportsconnection
toa10Mbps,100Mbps,or1000Mbpsnetwork.Formoreinformation,see“ConfiguringtheEthernet
controller”onpage61
.
•IntegratedTrustedPlatformModule(TPM)
Thisintegratedsecuritychipperformscryptographicfunctionsandstoresprivateandpublicsecurekeys.
ItprovidesthehardwaresupportfortheTrustedComputingGroup(TCG)specification.Youcandownload
thesoftwaretosupporttheTCGspecification,whenthesoftwareisavailable.YoucanenableTPM
supportthroughtheSetupUtilityundertheSystemSecuritymenuoption.
•Largedata-storagecapacityandhot-swapcapability
Thehot-swapservermodelssupportamaximumoftwenty-six2.5-inchorfourteen3.5-inchhot-swap
SerialAttachedSCSI(SAS)harddiskdrivesorhot-swapSerialATA(SATA)harddiskdrives.The
simple-swapservermodelssupportamaximumofsixteen2.5-inchoreight3.5-inchsimple-swapSATA
harddiskdrives.
Withthehot-swapfeature,youcanadd,remove,orreplaceharddiskdriveswithoutturningofftheserver.
•Largesystem-memorycapacity
Theservercansupportupto1.5TBofsystemmemory.Theserverprovides24dualinlinememory
module(DIMM)connectors.Theservermemorycontrollersupportserrorcorrectingcode(ECC)for
PC4-17000(DDR4-2400),DDR4(fourth-generationdouble-data-rate),synchronousdynamicrandom
accessmemory(SDRAM)DIMMs.
•MobileaccesstoServiceInformationwebsite
TheserverprovidesaQRcodeonthesystemservicelabel,whichisonthecoveroftheserver,thatyou
canscanusingaQRcodereaderandscannerwithamobiledevicetogetquickaccesstotheService
Informationwebsite.TheServiceInformationwebsiteprovidesadditionalinformationforpartsinstallation
andreplacementvideos,anderrorcodesforserversupport.FortheQRcode,seeQRcodeinformation
onpageChapter1“TheSystemx3650M5server”onpage1
.
•Multi-coreprocessing
TheserversupportsuptotwoIntelXeonE5-2600v4seriesmulti-coremicroprocessors.Theserver
comeswithaminimumofonemicroprocessor.
•PCIadaptercapabilities
TheserverhastwoPCIinterfacerisers.See“Replacinganadapter”onpage196fordetailedinformation.
•SDadapter
AraidcontrollerforSecureDigital(SD)media.Ithastwoupstreamconnections,aUSBconnectiontothe
serverchipset,andanMMCconnectiontotheIMM2.1.
•Redundantconnection
TheadditionoftheoptionalEthernetadapterprovidesfailovercapabilitytoaredundantEthernet
connectionwiththeapplicableapplicationinstalled.IfaproblemoccurswiththeprimaryEthernet
connectionandtheoptionalEthernetadapterisinstalledontheserver,allEthernettrafficthatis
associatedwiththeprimaryconnectionisautomaticallyswitchedtotheoptionalredundantEthernet
adapterconnection.Iftheapplicabledevicedriversareinstalled,thisswitchingoccurswithoutdataloss
andwithoutuserintervention.
•Redundantcoolingandoptionalpowercapabilities
Theserversupportsamaximumoftwo550-watt,750-watt,900-watt,1300-wattor1500-watthot-swap
powersuppliesandsixhot-swapfans,whichprovideredundancyandhot-swapcapabilityforatypical
configuration.Theredundantcoolingbythefansintheserverenablescontinuedoperationifoneof
thefansfails.Theservercomeswiththeminimumofone550-watt,750-watt,900-watt,1300-wattor
1500-watthot-swappowersupplyandfourfans.Iftwoormorefansfail,yourserverwillautomatically
turnoffaftersixminutesduetothermallimitation.
Chapter1.TheSystemx3650M5server15