Loading...
2.5-inch HDD hot-swap backplane
Power / configuration cable
SAS signal cable
Power / configuration cable
Signal cable
2.5-inch NVMe backplane
2.5-inch HDD hot-swap backplane
Power / configuration cable
SAS signal cable
Figure293.Cableconnections
Step8.Touchthestatic-protectivepackagethatcontainstheNVMeadaptertoanyunpaintedmetal
surfaceontheserver.Then,removetheNVMeadapterfromthepackage.
Step9.RemovethePCIriser-cardassemblies.(see“Removingariser-cardassembly”onpage186).
Step10.InstallNVMeadaptersintothePCIconnectorsonthePCIrisercardorthesystemboard(see
“Replacinganadapteronpage196).
Attention:Incompleteinsertionmightcausedamagetotheserverortheadapter.
Step11.ConnectthefoursignalcablestotheconnectorsontheNVMeadapter:
NVMe adapter
Port 1 Port 0
Figure294.NVMeadapterconnectors
Step12.AlignandinstallthePCIriser-cardassembliesintheserver(see“Replacingariser-cardassembly”
onpage188).
Step13.Routethecablesunderneaththecableretention.
8x2.5-inchHDD+4x2.5-inchNVMePCIeSSD
Chapter5.Installing,removing,andreplacingcomponents321