Troubleshooting and fault elimination
Drive behaviour in the event of faults
8
184
EDK82EV903 DE/EN/FR 5.1
8.2 Drive behaviour in the event of faults
The controller responds differently to the three possible fault types (TRIP, message, or
warning):
TRIP (keypad display: ")
ƒ Switches the power outputs U, V, W to high resistance until TRIP is reset.
ƒ The fault indication is entered into C0161 of the history buffer as "current fault".
ƒ The drive coasts without control!
ƒ After TRIP reset ( 189):
The drive accelerates to its setpoint along the set ramps.
The fault indication is moved to C0162 as "last fault" and is deleted in C0161.
Messages (keypad display: )
ƒ Switches the power outputs U, V, W to high resistance.
ƒ Messages are not entered into the history buffer.
ƒ The drive coasts without control as long as the message is active!
ƒ If the message is no longer active, the drive starts automatically.
Warnings
"Heatsink overtemperature" (keypad:OH #)
ƒ The drive is operated in a controlled mode!
ƒ The warning signal goes off if the fault is no longer active.
"Error in motor phase" (keypad:LP1)
"PTC monitoring" (keypad:OH51)
ƒ The drive is operated in a controlled mode!
ƒ The fault indication is entered into C0161 of the history buffer as "current fault".
ƒ After TRIP reset the fault indication is moved to C0162 as "last fault" and is deleted
in C0161.

Table of Contents

Other manuals for Lenze 8200 vector series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8200 vector series and is the answer not in the manual?

Lenze 8200 vector series Specifications

General IconGeneral
CategoryDC Drives
Overload capacity150% for 60 seconds
Protection classIP20
Mains voltage380V to 480V AC
Control methodVector control
Communication optionsCANopen
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Humidity≤ 95% relative humidity, non-condensing