Mechanical installation
Important notes
Mounting with fixing brackets (standard)
4
119
EDK82EV903 DE/EN/FR 5.1
4 Mechanical installation
4.1 Important notes
Warnings!
The scope of supply of the controller includes a label with the following text:
"Suitable for use on a circuit capable of delivering not more than ...".
If the controller is used in systems in accordance with UL, stick this label on the
controller before mounting. Select the position so that no ventilation hole and
no cooling ribs are covered.
The accessory kit is located inside the controller.
Remove the cover of the drive controller
0
1
1. Remove the screws
2. Lift cover up and detach it
9300vec113
4.2 Standard devices in the power range 15 ... 30 kW
4.2.1 Mounting with fixing brackets (standard)
Mounting material required from the scope of supply:
Description Use Quantity
Fixing bracket Drive controller fixing 4
Raised countersunk head screw
M5 × 10 mm (DIN 966)
Mounting of fixing bracket to the drive controller 4
Controller variant "2xx" (without fully assembled footprint filter)
For this mounting variant you require controller type E82EVxxxK4B2xx.
Note!
Before assembling the controller, please read the documentation for the
components connected on the supply side (mains choke, filter).

Table of Contents

Other manuals for Lenze 8200 vector series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lenze 8200 vector series and is the answer not in the manual?

Lenze 8200 vector series Specifications

General IconGeneral
CategoryDC Drives
Overload capacity150% for 60 seconds
Protection classIP20
Mains voltage380V to 480V AC
Control methodVector control
Communication optionsCANopen
Protection featuresOvercurrent, overvoltage, undervoltage, overtemperature, short circuit
Humidity≤ 95% relative humidity, non-condensing
Series8200 vector