EasyManua.ls Logo

Lenze EVS 9300 series - Page 122

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parameter setting
Parameter setting using the keypad
7-8
l
EDSVS9332S-D11 EN 3.0
Copying parameter set from the keypad into the basic device
Step Key sequence Action
1. Connect the keypad to the basic device 2
2. Inhibit controller: Terminal X5/28 = LOW
The drive coasts
3. Pull the plugs X5 and X6 All control terminals have the defined state ”LOW”.
4. Select C0002 in the menu ”Load/Store”

Select code C0002 ”PAR LOAD” in the menu ”Load/Store” using the
arrow keys.
5. Change to the parameter level
Display ”0” and ”Load Default”
6.
Select the correct copy function The settings stored in the basic device are overwritten.
Copy all available parameter sets into the basic device and save them permanently.
Set ”20” ”ext -> EEPROM”
Copy single parameter sets to the main memory.
Copy parameter set 1:
Set Ö ”11” ”Load ext PS1”
Copy parameter set 2:
Set Ö ”12” ”Load ext PS2”
Copy parameter set 3:
Set Ö ”13” ”Load ext PS3”
Copy parameter set 4:
Set Ö ”14” ”Load ext PS4”
7. Start copying

”RDY” goes OFF. ”BUSY” is displayed.
When ”BUSY” goes off, the selected parameter sets are c opied to the
basic device.
8.
Change to the code level
A)
Display of the operating level
B)
Display C0002 and ”PAR LOAD”
9. If necessary, store separately copied parameter
sets

Select code C0003 ”PAR SAVE” in the menu ”Load/Store” using the
arrow keys and permanently store the contents of the main memory.
10. Plug in plugs X5 and X6
11. Enable controller Terminal X5/28 = HIGH
The drive is running with the new settings.