Function library
Working with function blocks
9-44
L
EDSVS9332S-D11 EN 3.0
Estab lish connections
1. Determine the signal source for ARIT2-IN1:
Change to the code level using the arrow keys
Select C0601/1 using or .
Change to the parameter level using PRG.
Select output AIN2-OUT (selection number 55) using or .
–ConfirmusingSH+PRG
Change to the code level again using PRG.
2. Determine signal source for ARIT2-IN2:
Select C0601/2 using .
Change to the parameter level using PRG.
Select output AIN2-OUT (selection number 55) using or .
–ConfirmusingSH+PRG
Change to the code level again using PRG.
3. Parameterise ARIT2:
Select C0600 using .
Change to the parameter level using PRG.
Select multiplication (selection number 3).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
4. Determine signal source for AOUT1:
Select C0431 using .
Change to the parameter level using PRG.
Select output ARIT2-OUT (selection number 5505).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
5. Enter function block ARIT2 in the processing table:
Select C0465 and subcode 8 using .
Change to the parameter level using PRG.
Enter function block ARIT2 (selection number 5505).
–ConfirmusingSH+PRG
Change to the code level again using PRG.
The sequence of the FB processing is thus determined.