Function library
Function blocks
9.2.18 Signal conversion (CONV)
9-84
L
EDSVS9332S-D11 EN 3.0
CONV6
C O N V 6
C O N V 6 - O U T
C O N V 6 - I N
C 1 1 7 3
C 1 1 7 2
C 1 1 7 0
C 1 1 7 1
Fig. 9-47 Function block CONV6
Signal
Source Note
Name Type DIS DIS format CFG List Lenze
CONV6-IN a C1173 dec [%] C1172 1 1000
CONV6-OUT phd - - - - - Limited to ±29999 rpm
This function block is used to convert analog signals into speed signals.
The conversion is done according to the formula:
CONV6-OUT = CONV6-IN
15000rpm
100%
C1170
C1171