EasyManua.ls Logo

Lenze EVS 9300 series - Page 237

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Function library
Function blocks
9.2.28 Digital frequency processing (DFSET)
9-111
L
EDSVS9332S-D11 EN 3.0
Function
z Setpoint conditioning with stretch and gearbox factor
z Processing of correction values
z Synchronising to zero track or touch probe (for resolver feedback touch probe only)
z Suppressing fault signals when synchronising via touch probe
9.2.28.1 Setpoint conditioning with stretching and gearbox factor
Stretching factor
Defines the ratio between the drive and the setpoint.
z The stretching factor evaluates the setpoint at DFSET-IN. DFSET-POUT outputs the result.
z The stretching factor results from numerator and denominator.
Numerator is variable from analog signal source or fixed value by the code.
Input of the denominator under C0533.
z Relationship:
DFSET–POUT = DFSET–IN
DFSET–VP–DIV
C0533
Gearbox factor
Defines the transmission ratio of the drive. Enter the ratio of the drive.
z The gearbox factor evaluates the setpoint at DFSET-IN multiplied by the stretching factor.
DFSET-NOUT outputs the result.
z The gearbox factor results from numerator and denominator.
Numerator is variable from analog signal source or fixed value by the code.
Input of the denominator under C0033.
z Relationship:
DFSET–NOUT = Reckfaktor
DFSET–RATDIV
C0033
DFSET–NOUT = DFSET–IN
DFSET–VP–DIV
C0533
DFSET–RAT–DIV
C0033

Table of Contents

Related product manuals