Function library
Function blocks
9.2.40 Internal motor control (MCTRL)
9-137
L
EDSVS9332S-D11 EN 3.0
Signal Source Note
Name Type DIS DIS format CFG List Lenze
MCTRL-PHI-SET ph C0908 dec [inc] C0894 3 1000 Phase controller input for difference of set
phase to actual phase
MCTRL-N-SET a C0906/1 dec [%] C0890 1 5050 Speed setpoint input
MCTRL-M-ADD a C0906/2 dec [%] C0891 1 1000 Additional torque setpoint or torque
setpoint
MCTRL-LO-MLIM a C0906/3 dec [%] C0892 1 5700 Lower torque limitation in % of C0057
MCTRL-HI-MLIM a C0906/4 dec [%] C0893 1 19523 Upper torque limitation in % of C0057
MCTRL-PHI-LIM a C0906/5 dec [%] C0895 1 1006 Influence of phase controller in % of nmax
C0011
MCTRL-N2-LIM a C0906/6 dec [%] C0896 1 1000 Lower speed limit at speed limitation
MCTRL-FLDWEAK a C0906/7 dec [%] C0898 1 1006 Motor excitation
MCTRL-I-SET a C0906/8 dec [%] C0901 1 1006 Input for setting the I component of the
speed controller
MCTRL-P-ADAPT a C0906/9 dec [%] C0903 1 1006 Influence in % on VP of C0254; the
absolute value is processed (without sign)
MCTRL-PHI-ON d C0907/1 bin C0897 2 1000 HIGH = Activation of phase controller
MCTRL-N/M-SWT d C0907/2 bin C0899 2 1000 LOW = active speed control
HIGH = active torque control
MCTRL-QSP d C0907/3 bin C0900 2 10250 HIGH = drive performs QSP
MCTRL-I-LOAD d C0907/4 bin C0902 2 1000 HIGH = I component of the n-controller is
accepted by MCTRL-I-SET
MCTRL-PHI-ACT phd - - - - -
MCTRL-PHI-ANG ph - - - - - 65536 inc = one revolution
MCTRL-NACT a - - - - - in % of nmax (C0011)
MCTRL-PHI-ANA a - - - - - Actual phase value as analog signal
90 degrees = 100%
MCTRL-MACT a - - - - - in % of Mmax (C0057)
MCTRL-MSET2 a - - - - - in % of Mmax (C0057)
MCTRL-NSET2 a - - - - - in % of nmax (C0011)
MCTRL-DCVOLT a - - - - - 100% = 1000V
MCTRL-QSP-OUT d - - - - - HIGH = drive performs QSP
MCTRL-MMAX d - - - - - HIGH = speed controller operates within the
limits
MCTRL-IMAX d - - - - - HIGH = drive operates at the current limit
C0022
MCTRL-IACT a - - - - - -