Function library
Function blocks
9.2.40 Internal motor control (MCTRL)
9-139
L
EDSVS9332S-D11 EN 3.0
9.2.40.3 Torque limitation
Via the inputs MCTRL-LO-M-LIM and MCTRL-HI-M-LIM an external torque limitation can be set.
This serves to set different torques for the quadrants driving and braking.
z MCTRL-HI-M-LIM is the upper torque limit in [%] of the max. possible torque (C0057).
z MCTRL-LO-M-LIM is the lower torque limit in [%] of the max. possible torque (C0057).
z In case of quick stop (QSP) the torque limitation is deactivated.
Stop!
Only set positive values in MCTRL-HI-M-LIM and negative values in MCTRL-LO-M-LIM, otherwise
the speed controller may lose control. The drive may accelerate uncontrollably.