Function library
Function blocks
9.2.44 Motor potentiometer (MPOT)
9-159
L
EDSVS9332S-D11 EN 3.0
Tir
Tir
Tir
Tif
MPOT1-UP
MPOT1-DOWN
C0260
C0261
0
+
-
MPOT1-OUT
Fig. 9-108 Control signals of the motor potentiometer
In addition to the digital signals MPOT1-UP and MPOT1-DOWN another digital input exists
(MPOT1-INACT).Theinput MPOT1-INACTis used to activateordeactivatethemotorpotentiometer
function. Logic 1 at this input deactivates the motor potentiometer function. The input
MPOT1-INACT has priority over the inputs MPOT1-UP and MPOT1-DOWN.
When the motor potentiometer is deactivated, the motor potentiometer output (MPOT1-OUT)
follows the function set under C0264. The following functions can be set under C0264: