Function library
Function blocks
9.2.64 Multi-axis synchronisation (SYNC1)
9-209
L
EDSVS9332S-D11 EN 3.0
Function
z Possible axis synchronisations (chapter 9.2.64.1)
z Cycle times (chapter 9.2.64.2)
z Phase displacement (chapter 9.2.64.3)
z Synchronisation window for synchronisation via terminal (SYNC WINDOW) (chapter 9.2.64.4)
z Correction value of phase controller (SYNC CORRECT) (chapter 9.2.64.5)
z Fault indications (chapter 9.2.64.6)
z Configuration examples (chapter 9.2.64.7)
z Scaling (chapter 9.2.64.8)
9.2.64.1 Possible axis synchronisations
Operating mode
Code Value Function
C1120
0 FB without function.
Assigns the data at the inputs directly to the outputs.
1 CAN Sync active
Synchronises the controllers to the sync telegram of the system bus.
2 Terminal Sync active
Synchronises the controllers to the sync signal of terminal X5/E5.
Synchronisation time
After mains connection and initialisation time of the controller, the FB SYNC1 also requires a
synchronisation time.
The synchronisation time depends on
z the baud rate of the system bus (CAN-SYNC),
z the starting time (input of the first SYNC telegram / signal),
z the time between the SYNC telegrams,
z the SYNC correction factor (C0363),
z the operating mode of the FB SYNC1.