Function library
Code table
9-277
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0698
-2147483647 {1} 2147483647
1 (C0697/1)
2 (C0697/2)
[C0700] IN 19523 FCODE-472/3 →Selection list 1 ANEG1
Configuration - analog input signal
C0701 (C0700) -199.99 {0.01 % } 199.99
[C0703] IN 1000 FIXED0% →Selection list 1 ANEG2
Configuration - analog input signal
C0704 (C0703) -199.99 {0.01 % } 199.99
C0710 FUNCTION 0 0
1
2
Rising edge
Falling edge
Both edges
TRANS1
Function selection (signal evaluation)
C0711 PULSE T 0.001 0.001 {0.001 s} 60.000 TRANS1
Pulse time of TRANS1
[C0713] IN 1000 FIXED0 → Selection list 2 TRANS1
Configuration - digital input signal
C0714 (C0713)
C0715 FUNCTION 0 0
1
2
Rising edge
Falling edge
Both edges
TRANS2
Function selection (signal evaluation)
C0716 PULSE T 0.001 0.001 {0.001 s} 60.000 TRANS2
Pulse duration
[C0718] IN 1000 FIXED0 → Selection list 2 TRANS2
Configuration - digital input signal
C0719 (C0718)
C0720 FUNCTION 2 0
1
2
On delay
Off delay
On/off delay
DIGDEL1
Function selection
C0721 DELAY T 1.000 0.001 {0.001 s} 60.000 DIGDEL1
Delay time
[C0723] IN 1000 FIXED0 → Selection list 2 DIGDEL1
Configuration - digital input signal
C0724 (C0723)
C0725 FUNCTION 2 0
1
2
On delay
Off delay
On/off delay
DIGDEL2
Function selection
C0726 DELAY T 1.000 0.001 {0.001 s} 60.000 DIGDEL2
Delay time
[C0728] IN 1000 FIXED0 → Selection list 2 DIGDEL2
Configuration - digital input signal
C0729 (C0728)
C0730 MODE 0 0
1
Start measurement
Stop measurement
OSZ
Start / stop of the measuring value recording
C0731 STATUS 0
1
2
3
4
5
Measurement completed
Measurement active
Trigger detected
Cancel
Cancel after trigger
Read memory
OSZ
Current operating status
C0732 →Selection list 1
OSZ
1 CHANNEL1 1000 FIXED0%
Configuration - analog input signals
2 CHANNEL2 1000 FIXED0%
3 CHANNEL3 1000 FIXED0%
4 CHANNEL4 1000 FIXED0%
C0733 → Selection list 2
OSZ
1 DIG. TRIGGER 1000 FIXED0
T
igge
inpu
Configuration - digital input signal