Function library
Code table
9-286
l
EDSVS9332S-D12 EN 3.0
Code ImportantPossible settings
No. SelectionLenzeLCD
C0884
1 PAR*1
2 PAR*2
2 PAR-LOAD
[C0885] R 51 DIGIN1 → Selection list 2 R/L/Q
Clockwise rotation
Configuration - digital input signal
[C0886] L 52 DIGIN2 → Selection list 2 R/L/Q
Counter-clockwise rotation
Configuration - digital input signal
C0889
1 (C0885)
2 (C0886)
[C0890] N-SET 5050 NSET-NOUT →Selection list 1 MCTRL
Configuration - speed setpoint input
[C0891] M-ADD 1000 FIXED0% →Selection list 1 MCTRL
Configuration - torque setpoint input
[C0892] LO-M-LIM 5700 ANEG1-OUT →Selection list 1 MCTRL
Configuration - lower torque limit
[C0893] HI-M-LIM 19523 FCODE-472/3 →Selection list 1 MCTRL
Configuration - upper torque limit
[C0894] PHI-SET 1000 FIXED0INC → Selection list 3 MCTRL
Configuration - rotor position setpoint
[C0895] PHI-LIM 1006 FIXED100% →Selection list 1 MCTRL
Configuration phase controller limit
[C0896] N2-LIM 1000 FIXED0% →Selection list 1 MCTRL
Configuration - 2nd speed limitation value
[C0897] PHI-ON 1000 FIXED0 → Selection list 2 MCTRL
Configuration - switch-on signal of phase
controller
[C0898] FLD-WEAK 1006 FIXED100% →Selection list 1 MCTRL
Signal for field weakening
[C0899] N/M-SWT 1000 FIXED0 → Selection list 2 MCTRL
Changeover between n and M control
[C0900] QSP 10250 R/L/Q-QSP → Selection list 2 MCTRL
Control signal for release
[C0901] I-SET 1000 FIXED0% →Selection list 1 MCTRL
Load I-component of the speed controller
[C0902] I-LOAD 1000 FIXED0 → Selection list 2 MCTRL
Trigger signal for loading the I-component of
speed controller
[C0903] P-ADAPT 1006 FIXED100% →Selection list 1 MCTRL
Phase controller adaptation
C0906
-199.99 {0.01 %} 199.99
MCTRL
1 N-SET
Analog input signals
2 M-ADD
3 LO-M-LIM
4 HI-M-LIM
5 PHI-LIM
6 N2-LIM
7 FLD-WEAK
8 I-SET
9 P-ADAPT