Function library
Selection lists
9.5.3 Motor selection lists
9-318
L
EDSVS9332S-D12 EN 3.0
Three-phase asynchronous motors
The following table contains all asynchronous motors which can be selected via code C0086.
The ”Reference list of asynchronous motors” contains the asynchronous motors, the data of which
must be entered manually. ( 9-320)
01
9300VEC058
Fig. 9-192 Nameplate of a Lenze motor
Lenze type
designation
C0081
P
r
[kW]
C0087
n
r
[rpm]
C0088
I
r
[A]
C0089
f
r
[Hz]
C0090
U
r
[V]
Motor type Temperature sensor
210 DXRAXX071-12-50 DXRAXX071-12 0.25 1410 0.9
211 DXRAXX071-22-50 DXRAXX071-22 0.37 1398 1.2
212 DXRAXX080-12-50 DXRAXX080-12 0.55 1400 1.7
213 DXRAXX080-22-50 DXRAXX080-22 0.75 1410 2.3
214 DXRAXX090-12-50 DXRAXX090-12 1.10 1420 2.7
215 DXRAXX090-32-50 DXRAXX090-32 1.50 1415 3.6
216 DXRAXX100-22-50 DXRAXX100-22 2.20 1425 4.8
synch
onous
217 DXRAXX100-32-50 DXRAXX100-32 3.00 1415 6.6
50 400
inverter motor
Thermal contact
218 DXRAXX112-12-50 DXRAXX112-12 4.00 1435 8.3
(star connection)
219 DXRAXX132-12-50 DXRAXX132-12 5.50 1450 11.0
220 DXRAXX132-22-50 DXRAXX132-22 7.50 1450 14.6
221 DXRAXX160-12-50 DXRAXX160-12 11.00 1460 21.0
222 DXRAXX160-22-50 DXRAXX160-22 15.00 1460 27.8
223 DXRAXX180-12-50 DXRAXX180-12 18.50 1470 32.8
224 DXRAXX180-22-50 DXRAXX180-22 22.00 1456 38.8
225 30kW-ASM-50 - 30.00 1470 52.0
226 37kW-ASM-50 - 37.00 1470 66.0
synch
onous
227 45kW-ASM-50 - 45.00 1480 82.0
50 400
inverter motor
_
228 55kW-ASM-50 - 55.00 1480 93.0
(star connection)
_
229 75kW-ASM-50 - 75.00 1480 132.0