EasyManua.ls Logo

Lenze EVS 9300 series - Page 62

Lenze EVS 9300 series
504 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Installation
Electrical installation
4.2.8 Motor temperature monitoring
4-34
L
EDSVS9332S-B EN 3.0
Connection to the controller
MONIT-OH8
T2
T1
15 V
93xx
J
3.3 k
7.4 k
2.7 k
9300VEC017
Fig. 4-13 Input circuit for the connection of the measuring sensor
Types 9321 to 9326
Types 9327 and 9329
UVW
PE
U
V
W
X10
T1 T2
1
5
PE
T1
T2
U V W
Fig. 4-14 Connections T1 and T2 at the controller
Types 9330 and 9331
Type 9332
T1
T2
PE
UV W
T1
T2
PE
U
VW
Fig. 4-15 Connections T1 and T2 at the controller
Tip!
The prefabricated Lenze system cables for Lenze servo motors already include the cable for
temperature feedback. The cables are designed for a wiring according to EMC.
If you fabricate your own cables, the cables must always be separated from the motor cables.

Table of Contents

Related product manuals