Commissioning
5.1 Initial switch-on
5-3
L
EDSVS9332S-C EN 3.0
Tip!
For this application, you may use one of the predefined configurations in C0005.C0005 = XX1X(e.g.
1010 = speed control via terminals) automatically assigns the output X5/A1 to FIXED1.
9. Set the maximum speed under C0011.
10.Select a direction of rotation (see Chapter 5.4):
Clockwise rotation: HIGH signal (+13 V ... +30 V)on X5/E1
Counter-clockwise rotation: HIGH signal (+13 V ... +30 V) on X5/E2
11.Apply setpoint:
Apply a voltage > 0 V (max. 10 V) at X6/1, X6/2.
Do not activate a JOG setpoint (X5/E3 LOW).
12.Check whether the controller is ready for operation:
When green LED is blinking:
Controller is ready for operation, proceed with 13.
When green LED is OFF and red LED is blinking:
A fault has occurred. Eliminate the fault before proceeding with the commissioning (see
chapter 10 Troubleshooting and fault elimination”).
13.Enable controller (see Chapter 5.3):
The green LED is lit if a HIGH signal (+13 V ...+30 V) is applied to X5/28 and no other source
of the controller inhibit is active.
14.For operation with a fieldbus module, additional settings are necessary (see Operating
Instructions for the fieldbus module used).
The motor will now rotate with the setpoint speed and the selected direction of rotation.
Troubleshooting:
Error Cause / remedy
Feedback system Motor rotates CCW with view on motor shaft
C0060 counts down after controller enable
Feedback system is not connected in-phase
Connect feedback system in-phase
Asynchronous motor Motor
rotates at I
max
and half slip frequency
does not react on setpoint changes
Motor is not connected in-phase
C
o
n
n
e
c
t
m
o
t
o
r
i
n
p
h
a
s
e
a
t
t
h
e
t
e
r
m
i
n
a
l
s
U
V
W
Synchronous motor
Motor does not follow the setpoint change
Imax follows the setpoint in idle running
Connec
t
mo
t
o
r
in-phase a
t
t
he
t
e
r
minals U,
V
,W
Motor rotates CCW with view on the motor shaft. The rotor angle (offset of electrical and mechanical rotor
angle) is not correct
Adjust the rotor position (C0095 = 1). For this
purpose, the motor must be operated without any
load.