Z-Max Advanced Programming & Systems Design Guide rac00-sdg
Revision A:11/2005 Page 153
Step 2: Repair any short circuits before continuing.
Step 3: Install wire jumpers, one pair at a time (not supplied) to the Luma-Net
Connector on either end of the cable run between pins 1-2, then 2-3,
then 3-4
Step 4: Retest each the following wire pairs at each connector:
1-2 Short
2-3 Open
3-4 Short
Step 5: Make any necessary repairs and remove wire jumpers before continuing.