Page #149 background image
IOP and IOA Module Specifications
32-port Channelized T1/E1 FR/IP IOM
Beta Draft Confidential
CBX 500 Multiservice WAN Switch Hardware Installation Guide 4/5/03A-9
Any of the 32 physical ports can be selected as the timing source of port timing
reference A or port timing reference B
Module LED Status
Port Alarm Status
Figure A-9 shows the 32-Port Channelized T1/E1 FR/IP IOP and IOA modules..
Table A-2. Module LED Status Indicators
LED State Status
Good LED lit Normal operation
Failed LED lit Module failure
Redundant LED lit Redundant module online
Note: Not supported in this release.
Good and Failed LEDs blinking
simultaneously
Operating system software image currently being
downloaded from active switch processor (SP)
Table A-3. Port Alarm Status Indicators
LED State Status
Yellow LED lit Downstream equipment sees loss of signal resulting in a
remote alarm identification (RAI)
Red LED lit Loss of frame or signal
Red LED blinking Downstream equipment failure resulting in an alarm
indication signal (AIS)

Table of Contents

Other manuals for Lucent Technologies CBX 3500

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies CBX 3500 and is the answer not in the manual?

Lucent Technologies CBX 3500 Specifications

General IconGeneral
BrandLucent Technologies
ModelCBX 3500
CategorySwitch
LanguageEnglish

Related product manuals