NTP-004: Acceptance 363-206-285
Page2of6 Issue3,June2001
DDM-2000 OC-3 MULTIPLEXER
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
2.
!
CAUTION:
The
init-sys:all
command should NOT be used on an
in-service system.
NOTE:
During installation and/or initial testing, provisionable
parameters may have been set which need to be reset to
default values. STS-1 and/or VT1.5 (DS1) cross-connections
may have been made which should be deleted before the
system is placed in service. The init-sys:all command
will reset all provisionable parameters and
cross-connections to default values. If parameters have
already been set to their proper values and you are sure they
are set correctly, you may not want to perform this step.
Some parameters will have to be reset later before service is
established.
NOTE:
An inconsistent DCC values alarm will occur when the
init-sys:all command is executed, if fecom has not
been enabled at both ends of the system.
If required, use the command init-sys:all to reset
provisionable parameters to default values.

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals