INIT-PM INIT-PM
DDM-2000 OC-3 Issue 3 June 2001 11-125
NAME
init-pm: Initialize Performance Monitoring (PM)
INPUT FORMAT
init-pm:reg=
Register
;
DESCRIPTION
This command initializes all
current
day and/or all
current
quarter-hour
performance-monitoring storage registers. Registers for previous day and previous
quarter-hours are not affected.
NOTE:
If security is enabled on any CIT or DCC port on a shelf, then this command is
available to privileged users only for all CIT or DCC ports on the shelf.
The input parameter is:
RELATED COMMANDS
rtrv-pm-line
rtrv-pm-sect
rtrv-pm-sts1
rtrv-pm-t3
rtrv-pm-tca
rtrv-pm-t1
rtrv-pm-vt1
reg
Register is the class of registers to be initialized and may be one
of the following:
day Day registers
qh Quarter-hour registers
all Day and quarter-hour registers