NTP-020: System Turnup 363-206-285
Page 1 of 8 Issue 2, February 2000
DDM-2000 OC-3 MULTIPLEXER
Establish Initial End-to-End DS3-to-DS1 Service
(TMUX Group Equipped But Not In Service)
DO ITEMS BELOW IN ORDER LISTED. . . . . FOR DETAILS, GO TO
1.
!
CAUTION:
DDM-2000 circuit packs contain static sensitive components
which can be damaged by electrostatic discharge. A static
ground wrist strap must be worn when handling the circuit
packs. See electrostatic discharge considerations in
Trouble
Clearing: TAD-100
.
NOTE:
The OC-3 system must be established before continuing
with this procedure. If all the nodes of the network have not
been equipped and installed, refer to System
Turnup/Circuit Order: IXL-001 for procedures to equip the
DDM-2000 shelves, and to establish a system.
NOTE:
This procedure assumes that TMUX circuit packs have
already been installed during the initial shelf turnup at the
DS3 terminating end(s) of the circuit and either DS1 or
STS1E circuit packs have been installed during initial shelf
turnup at the other terminating end of the circuit. If the
appropriate circuit packs have not been installed and the
system is in service on other groups, refer to System
Turnup/Circuit Order: IXL-001 for procedures to add a new
DS3 group for DS3-to-DS1 service.
TAD-100

Table of Contents

Other manuals for Lucent Technologies DDM-2000 OC-3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Lucent Technologies DDM-2000 OC-3 and is the answer not in the manual?

Lucent Technologies DDM-2000 OC-3 Specifications

General IconGeneral
BrandLucent Technologies
ModelDDM-2000 OC-3
CategoryMultiplexer
LanguageEnglish

Related product manuals